Bug #1621

Broken parameter name translation for certain names in GUI fitting job

Added by pospelov over 3 years ago. Updated over 3 years ago.

Status:ArchivedStart date:01 Nov 2016
Priority:HighDue date:
Assignee:herck% Done:

0%

Category:-
Target version:Sprint32

Description

GUI fitting job is crashing when trying to fit following properties

  • MultiLayer "Cross correlation length"
  • Interference2DLattice/HexagonalLatticeType/Lattice_length
  • Beam wavelength, phi_f, alpha_f
  • And probably many more

This is a crucial bug which will be immediately discovered during tutorial.

Within this item
  • write new functional test GUITranslationTest (almost done already)

it will automatically run through all simulation's and check correctness of GUI->Core fit parameter translations

  • fix all key translations GUI->Core for fit parameter names
Additional bug discovered:
  • If instrument is named "Instrument" then all ModelPath::pathToIndex and similar are broken

Because of JobItem::P_INSTRUMENT with conflicting tag

History

#1 Updated by herck over 3 years ago

  • Assignee changed from pospelov to herck

#2 Updated by herck over 3 years ago

  • Status changed from Sprint to Resolved

#3 Updated by herck over 3 years ago

  • Status changed from Resolved to Archived

Also available in: Atom PDF