Bug #2356

Undefined state in Instrument > Polarization analysis > Analyzer orientation and efficiency

Added by wuttke 7 months ago. Updated 7 months ago.

Status:NewStart date:13 May 2019
Priority:NormalDue date:
Assignee:-% Done:

0%

Category:-
Target version:-

Description

In the GUI, it is possible to set a nonzero analyzer efficiency
while the analyzer orientation is still (0,0,0). This is unphysical.

Should we enforce that the analyzer orientation be a unit vector?

The meaning of "efficieny" and "transmission" is not obvious and
unambiguous. Transmission of the good or the bad polarization??
If no better parameterization can be found, then at least provide
information in a tooltip.


Related issues

Related to BornAgain - Bug #2416: Polarization: Fix treatment of imperfect analyzers Backlog 20 Nov 2019

History

#1 Updated by wuttke 7 months ago

  • Description updated (diff)

#2 Updated by wuttke 7 months ago

  • Description updated (diff)

#3 Updated by dmitry 17 days ago

  • Related to Bug #2416: Polarization: Fix treatment of imperfect analyzers added

Also available in: Atom PDF